HCDOES home P&E home Our logo for Air quality


Colerain Township
PM10 Monitoring Results

Note: The 24-hour National Ambient Air Quality Standard for

PM10 is 150 micrograms per cubic meter (µg/m3). Two PM10 monitors are located in Colerain Township. One monitor located off Hughes Road began collecting data January 2007. An additional monitor was added in the area with the first sample collected on August 5, 2009. The Hughes Road Sampler ceased to collect samples May 31, 2010. All results are in micrograms per cubic meter (µg/m3).


 

Date Struble & Colerain (µg/m3)
09-30-2011 13.5
09-24-2011 11.0
09-18-2011 14.1
09-12-2011 Machine Malfunction
09-06-2011 25.1
08-31-2011 28.0
08-25-2011 31.5
08-19-2011 34.9
08-13-2011 21.9
08-07-2011 20.0
08-01-2011 77.4**
07-26-2011 61.9
07-20-2011 45.1
07-14-2011 27.1
07-08-2011 34.5
07-02-2011 52.8
06-26-2011 16.5
06-20-2011 24.4
06-14-2011 66.7
06-08-2011 61.6
06-02-2011 107.5
05-27-2011 28.3
05-21-2011 42.3
05-15-2011 6.3
05-09-2011 23.1
05-03-2011 29.1
04-27-2011 15.7
04-21-2011 52.1
04-15-2011 22.8
04-09-2011 32.1
04-03-2011 14.4
03-28-2011 49.3
03-22-2011 43.1
03-16-2011 26.7*
03-10-2011 10.9
03-04-2011 26.8
02-26-2011 22.0
02-20-2011 12.8
02-14-2011 27.6
02-08-2011 33.9
02-02-2011 11.4
01-27-2011 29.2
01-21-2011 18.5
01-15-2011 37.3
01-09-2011 39.0
01-03-2011 41.8

* March 16, 2011 - Road sweeping in vicinity of monitor during sampling event

** August 1, 2011 - Mowing of field where monitor is sited occurred during sampling event